You are using an outdated browser. Please update your browser now to display the page correctly.
Delivery the next working day
Right of return 14 days
Fresh-water storage tank for highest demands on drinking water hygiene and energy efficiency.
The structure of the storage tank is fundamentally different from usual large-volume domestic hot-water tanks...
Storage tanks A+
10-year warranty
High Quality
Clean fresh water generation in corrugated stainless steel pipe with flow heater principle
TÜV Rheinland
Delivery by forwarding agency
Fresh-water storage tank for highest demands on drinking water hygiene and energy efficiency.
The structure of the storage tank is fundamentally different from usual large-volume domestic hot-water tanks. A built-in corrugated stainless steel pipe separates the drinking water from the heating water, while serving as a powerful heat exchanger at the same time. Thus, the advantages of a buffer tank are combined with those of a continuous flow water heater.
The heating water serves as actual heat storage while the drinking water flows through the corrugated stainless steel pipe only if required and, thus, a legionella-safe domestic water heating is ensured. You do not need a protection programme against legionella in the controller. At all times, the consumer is provided with hygienically clean, fresh water at the desired temperature.
Due to the two additional smooth-pipe heat exchangers, more heat generators can be integrated at any time and their energy can be fed into the fresh-water storage tank.
For more information see Downloads
OEG no. | 516008294 |
Installation type: | Vertical storage tank |
Manufacturer | OEG |
Brand | Pure+ |
Energy efficiency class | A+ |
ErP-Label | |
Notes |
Storage tanks A+ 10-year warranty High Quality Clean fresh water generation in corrugated stainless steel pipe with flow heater principle TÜV Rheinland Delivery by forwarding agency |
Customs tariff number | 84191900 |
Rated volume according to EN 12897: | 300 |
Colour: | silver |
Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
Weight [kg]: | 110 |
Total height including insulation [mm]: | 1750 |
Diameter with insulation [mm]: | 610 |
Tilt height [mm]: | 1830 |
Energy efficiency class according to EU regulation no. 812/2013: | A+ |
Heat retaining loss according to EN 12897 [W]: | 36 |
Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,864 |
Output capacity (45°C) [l]: | 175 |
Performance indicator NL following DIN 4708: | 1,60 |
Real volume according to EN 12897 [l]: | 294 |
pmax Tank [bar]: | 3 |
tmax Tank [°C]: | 95 |
tmin Tank [°C]: | 20 |
DHW heat exchanger area [m²]: | 4,40 |
DHW heat exchanger volume [l]: | 19,30 |
pmax DHW heat exchanger [bar]: | 6 |
tmax DHW heat exchanger [°C]: | 95 |
Smooth-pipe heat exchanger [number]: | 2 |
Smooth-pipe heat exchanger area bottom [m²]: | 1,15 |
Smooth-pipe heat exchanger area top [m²]: | 0,77 |
Smooth-pipe heat exchanger volume bottom: | 7,50 |
Smooth-pipe heat exchanger volume top: | 5,05 |
pmax Smooth-pipe heat exchanger [bar]: | 10 |
tmax Smooth-pipe heat exchanger [°C]: | 130 |
Connection layout: | 180° |
Connection sensor [Ø mm / terminal]: | 6 mm |
Connection cold / hot water: | Rp 1 1/4" |
Connection heat generator [thread]: | R 1" |
Connection heat exchanger [thread]: | Rp 1" |
Connection heating element [thread]: | Rp 1 1/2" |
Max. immersion depth of screw-in heater [mm]: | 500 |
Beste, we hebben geen uitgebreide diagrammen voor de capaciteit van de warmtewisselaars. Maar er is wel het bulkvermogen aangegeven. Dit is een normgetal die aangeeft hoeveel liters water je uit de boiler haalt tot dat de temperatuur naar 45°C gedaald is wanneer de boiler eerst 60°C heeft, naarstromend water 10°C en de boiler niet naverwarmd wordt. Bij deze boiler zijn dat dan 175l. Dus indien je de boiler standaard op 80°C hebt staan dan is dat ruim voldoende voor een douche en een keuken tegelijk.
Een hydraulisch schema van mijn situatie zie ik niet op blz. 1108-1109, te weten woonkamer een houtkachel gekoppeld, c.v. voor verwarmen naar ketel op zolder, warmwater voorverwarmd naar c.v.-ketel op zolder, in de serre nabij het buffervat een vloerverwarming deze voeden uit buffervat. Is hiervoor een optie beschreven?
Om u van dienst te kunnen zijn hebben wij een schets nodig van het hydraulische schema hoe u installatie is opgebouwd. U kunt dit sturen naar: [email protected]