Thanks to the so-called tank-in-tank system, OEG combination storage tanks provide simultaneous heating, storage, and supply of heating and potable water.
The integrated potable water tank is automatically...
Thanks to the so-called tank-in-tank system, OEG combination storage tanks provide simultaneous heating, storage, and supply of heating and potable water.
The integrated potable water tank is automatically heated by the surrounding heating water. In this way, combination tanks effectively and space-efficiently unite the benefits of buffer tanks and potable water tanks. They are ideal for use with solar thermal systems for heating support and are also suitable for operation with multiple energy sources while requiring minimal control effort
For more information see Downloads
| OEG no. | 516005420 |
| Fresh water alternative: | 516008230 |
| Operating mode: | bivalent |
| Installation type: | Vertical storage tank |
| Manufacturer | OEG |
| Notes | |
| Customs tariff number | 73090059 |
| Colour: | silver |
| Insulation according to DIN 4102-1 Fire Protection Class B2: | removable segment insulation |
| Weight [kg]: | 350 |
| Total height including insulation [mm]: | 2355 |
| Required height for cover assembly [mm]: | 2630 |
| Diameter without insulation [mm]: | 790 |
| Diameter with insulation [mm]: | 1015 |
| Tilt height [mm]: | 2410 |
| Heat retaining loss according to EN 12897 [W]: | 55 |
| Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 1,320 |
| Output capacity (45°C) [l]: | 315 |
| Performance indicator NL following DIN 4708: | 7 |
| Real volume according to EN 12897 [l]: | 993 |
| pmax Tank [bar]: | 3 |
| tmax Tank [°C]: | 95 |
| tmin Tank [°C]: | 20 |
| Buffet storage tank capacity (part of the actual capacity) [l]: | 787 |
| Domestic hot water tank volume (Part of the real volume) [l]: | 206 |
| pmax Domestic hot water tank [bar]: | 10 |
| tmax Domestic hot water tank [°C]: | 95 |
| Smooth-pipe heat exchanger [number]: | 1 |
| Smooth-pipe heat exchanger area bottom [m²]: | 3,30 |
| Smooth-pipe heat exchanger volume bottom: | 21,30 |
| pmax Smooth-pipe heat exchanger [bar]: | 10 |
| tmax Smooth-pipe heat exchanger [°C]: | 130 |
| Connection layout: | 90° |
| Connection sensor [Ø mm / terminal]: | 6 mm |
| Connection cold / hot water: | R 3/4" |
| Connection heat generator [thread]: | Rp 1 1/2" |
| Connection heat exchanger [thread]: | Rp 1" |
| Connection circulation: | R 1/2" |
| Connection heating element [thread]: | Rp 1 1/2" |
| Service hatch (LK 150): | 115 / 180 |
| Max. immersion depth of screw-in heater [mm]: | 800 |
Vous recherchez le Set of gaskets for combined storage tanks ou un autre joint ?
Avec le ballon combiné, il est possible de le raccorder soit à une installation solaire, soit à un autre générateur de chaleur. Mais seule l'une des deux possibilités est possible, les deux ne peuvent malheureusement pas être combinées.
Deze isolatie is afneembaar, zodat het vat door een deur passt van ca. 800 mm breedte.
documents techniques envoyés par mail
Für die Heizungsseite, also den unteren Teil des Speichers mit dem „toten“ Heizungswasser, wird kein Manometer benötigt. Der Druck ist ja gleich dem Druck des Wärmeerzeugers. ( Gas- oder Ölkessel, Holzheizung was auch immer ) Dort muss eine Kesselsicherheitsgruppe mit Manometer und Sicherheitsventil verbaut sein.
Für die Trinkwasserseite ist normalerweise auch kein Manometer am Speicher selber vorgesehen. Der Wasseranschluss muss ja nach DIN / EN ausgeführt werden, also ggf. mit Druckminderer und vor allem MIT SICHERHEITSVENTIL. – Katalog Seite 783 und 785 -
Da das Wasser oben im Innentank sich ja bei Erwärmung ausdehnt, wird aus dem Sicherheitsventil IMMER etwas Wasser austreten.
Diese normgerechte Trinkwasserinstallation kann natürlich, zur Kontrolle des Sicherheitsventils, mit einem Manometer ausgerüstet sein.
WICHTIG BEI DER INBETRIEBNAHME:
Zuerst oben den Trinkwassertank befüllen.
Danach die untere Seite des Speichers.
Sicherheitsventile dürfen nicht abgesperrt sein !