Eckerle suction pump unit SP 32/8-80 M with mechanical anti-siphon valve

OEG no.: 120500070
  • Also replaces
    schließen Also replaces:
    • 120500060 (Suction pump unit Eckerle SP 32/8-40 M with mechanical anti-siphon valve)
Zoom Eckerle suction pump unit SP 32/8-80 M with mechanical anti-siphon valve

With electromagnetic reciprocating plunger type pump, float, control and safety functions, suction filter, 8 l oil tank, safety collector with leak detector and fault shut-off, LCD display for permanent...

All product information
Wipe 'n' Buy ®

With electromagnetic reciprocating plunger type pump, float, control and safety functions, suction filter, 8 l oil tank, safety collector with leak detector and fault shut-off, LCD display for permanent operation and fault monitoring with anti-siphon valves, either mechanical M (set to 1.80 m) or electric E (controlled through oil burner), pipe connection 10 x 1 mm, ready to plug-in
Fields of application:
Fully automatic suction pump for supplying oil burners up to max. 50 l/h nozzle output.
For single-line operation only
Technical data:
Electr. connection: 230 V / 50 Hz, 25 VA.
Max. capacity 40 l/h at 4 m suction head and 19 l/h
at 6.5 m suction head
Integrated check valve in suction pipe!
Dimensions (H xW x D): 380 x 400 x 260 mm
Weight: 7.5 kg
Design SP 32/8-80 M/E: delivery rate approx. 80 l/h at
2 m and 25 l/h at 6 m suction head.


For more information see Downloads


OEG no. 120500070
Also replaces
  • 120500060 (Suction pump unit Eckerle SP 32/8-40 M with mechanical anti-siphon valve)
Weight [kg] 7.8
Customs tariff number 84136039
en
Question:

Convient pour l alimentation d une cuisinière fioul

Answer OEG:

Le groupe de pompe d'aspiration de fioul SP32 02-80 est conçu pour alimenter les
brûleurs à fioul automatiques en fioul selon DIN EN 51603-1 EL et

DIN V 516036 EL A Bio 5 en fonctionnement par aspiration.

en
Question:

welcher Ölfilter wir am Brenner verwendet ?Ein Toc Duo ?

Answer OEG:

Es soll kein zusätzliches Rückschlagventil sowie Filter in die Saugleitung eingebaut werden, da dies bereits in der Pumpe vorhanden ist.

You have to be logged in to ask a question

No customer reviews yet

In order to give a review, you have to be logged in.