You are using an outdated browser. Please update your browser now to display the page correctly.
SIT830 has a double safety solenoid valve and is designed for the installation in appliances with automatic flame monitoring. All settings are accessible from above. The valve can be installed in any position...
All product informationSIT830 has a double safety solenoid valve and is designed for the installation in appliances with automatic flame monitoring. All settings are accessible from above. The valve can be installed in any position.
Note:
When ordering, always ensure the code number of the gas control block matches the existing number. This is essential for proper operation.
For more information see Downloads
| OEG no. | 132423250 |
| Voltage [V]: | 230 |
| Protection type [IP]: |
IP54 |
| Power consumption [W]: | 3.7 |
| Inlet pressure max. [bar]: | 0.05 |
| Outlet pressure [bar]: | 0.003 .. 0.05 |
| Ambient temperature [°C]: | 0 .. 60 |
| Type: | 830 Tandem |
| Manufacturer | SIT |
| Manufacturer number | 0830030 |
| Weight [kg] | 1 |
| Customs tariff number | 84818099 (IT) |
Kann eingesetzt werden.
Die Spulenkabel aber bitte mitbestellen sofern noch nicht der TANDEM 830 Regelblock verbaut ist (Connection cable for SIT solenoid).