You are using an outdated browser. Please update your browser now to display the page correctly.
Heating controller with rotary knob actuation and symbol-guided display for direct installation in the DIN shaft of all common boiler brands.
The controller is suitable for single or two-stage heat...
Unmixed boiler heating circuit
Mixer heating circuit 1
Heating controller with rotary knob actuation and symbol-guided display for direct installation in the DIN shaft of all common boiler brands.
The controller is suitable for single or two-stage heat generators, for a direct heating circuit and a mixed heating circuit and circulation pump as well as for a water charge pump.
DHR has a digital calendar clock with editable weekly time programmes, 3 heating and 1 hot water programme as well as two time channels for room heating and hot water.
The controller has a weather-compensated flow temperature control, optionally with or without room temperature control via a remote control.
The controller also offers automatic summer - winter switching for normal and reduced operation, room and frost protection function in stand-by mode and optimisation of the switch-on and switch-off times for heating operation.
DHR has the function of maximum and minimum limitation for heat generators and heating circuits.
For modulating gas boilers with OpenTherm input, the automatic burner control unit can be controlled directly using an interface, which is available as an option.
| Scope of delivery: | |||
| 1 x | regulation | ||
| 4 x | sensor | ||
| 1 x | operating instructions | ||
| 1 x | mounting kit | ||
| 1 x |
|
|
|
| OEG no. | 212300012 |
| Country version: | FR |
| Length x Width [mm]: | 144 x 96 |
| Model: | Comfort |
| Heating circuits: | 1 x mixed, 1 x unmixed |
| Manufacturer | OEG |
| Weight [kg] | 12.53 |
| Notes |
Unmixed boiler heating circuit Mixer heating circuit 1 |
| Customs tariff number | 90321020 |
Au chapitre 5.4, le bouton de réglage 7-0 permet de sélectionner si le circuit de chauffage doit fonctionner en circuit mélangeur (réglage d'usine) ou en circuit direct (réglage de 0 à 2). Il n'existe pas de schéma de câblage direct pour le DHR, car le régulateur offre des possibilités plus étendues. Le limiteur de température de sécurité doit être installé séparément. D'après la question posée, le tableau de commande de chaudière Boiler control panel with KMS-D heating controller semble être le produit le plus adapté. Il comprend un STL ; le schéma 102 correspond au circuit hydraulique demandé.