Fresh-water storage tank for highest demands on drinking water hygiene and energy efficiency.
The structure of the storage tank is fundamentally different from usual large-volume domestic hot-water tanks...
Storage tanks A+
10-year warranty
High Quality
Clean fresh water generation in corrugated stainless steel pipe with flow heater principle
TÜV Rheinland
Delivery by forwarding agency
Fresh-water storage tank for highest demands on drinking water hygiene and energy efficiency.
The structure of the storage tank is fundamentally different from usual large-volume domestic hot-water tanks. A built-in corrugated stainless steel pipe separates the drinking water from the heating water, while serving as a powerful heat exchanger at the same time. Thus, the advantages of a buffer tank are combined with those of a continuous flow water heater.
The heating water serves as actual heat storage while the drinking water flows through the corrugated stainless steel pipe only if required and, thus, a legionella-safe domestic water heating is ensured. You do not need a protection programme against legionella in the controller. At all times, the consumer is provided with hygienically clean, fresh water at the desired temperature.
Due to the additional smooth-pipe heat exchanger, a heat generators can be integrated at any time and its energy can be fed into the fresh-water storage tank.
For more information see Downloads
OEG no. | 516008266 |
Installation type: | Vertical storage tank |
Manufacturer | OEG |
Brand | Pure+ |
Energy efficiency class | A+ |
ErP-Label | |
Notes |
Storage tanks A+ 10-year warranty High Quality Clean fresh water generation in corrugated stainless steel pipe with flow heater principle TÜV Rheinland Delivery by forwarding agency |
Customs tariff number | 84191900 |
Rated volume according to EN 12897: | 300 |
Colour: | silver |
Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
Weight [kg]: | 98 |
Total height including insulation [mm]: | 1750 |
Diameter with insulation [mm]: | 610 |
Tilt height [mm]: | 1830 |
Energy efficiency class according to EU regulation no. 812/2013: | A+ |
Heat retaining loss according to EN 12897 [W]: | 36 |
Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,864 |
Output capacity (45°C) [l]: | 175 |
Performance indicator NL following DIN 4708: | 1,60 |
Real volume according to EN 12897 [l]: | 296 |
pmax Tank [bar]: | 3 |
tmax Tank [°C]: | 95 |
tmin Tank [°C]: | 20 |
DHW heat exchanger area [m²]: | 4,40 |
DHW heat exchanger volume [l]: | 19,30 |
pmax DHW heat exchanger [bar]: | 6 |
tmax DHW heat exchanger [°C]: | 95 |
Smooth-pipe heat exchanger [number]: | 1 |
Smooth-pipe heat exchanger area bottom [m²]: | 1,15 |
Smooth-pipe heat exchanger volume bottom: | 7,50 |
pmax Smooth-pipe heat exchanger [bar]: | 10 |
tmax Smooth-pipe heat exchanger [°C]: | 130 |
Connection layout: | 180° |
Connection sensor [Ø mm / terminal]: | 6 mm |
Connection cold / hot water: | Rp 1 1/4" |
Connection heat generator [thread]: | R 1" |
Connection heat exchanger [thread]: | Rp 1" |
Connection heating element [thread]: | Rp 1 1/2" |
Max. immersion depth of screw-in heater [mm]: | 500 |
Heeft u een aansliotschema voor mij, van dit vat en is dit inclusief isolatie?
Die kunt u in de handleiding vinden (klik bij het artikel op downloads, pagina 93)
Guten Tag,
hier sollte nichts dagegen sprechen.
Mit freundlichen Grüßen
klant heeft bestaande boiler 516008266 heeft u hiervan het juiste aansluitschema. momenteel in gebruik voor palletkachel Primair. Secundair warmwater en radiator verwarming. Wil uitbreiden met zonne celectoren. Welke boiler of set adviseert u en heeft u daar ook een aansluit schema van? Uit de download zie ik het niet. vr. gr. John
Het aansluitschema van de boiler vindt u in de downloads of in deze link (pagina 80 - handleiding boilers), om de juiste solarinstallatie te bepalen verzoek ik u het formulier "aanvraag thermische solarinstallatie" ingevuld naar [email protected] te sturen. Naar aanleiding van de uitkomst kunnen we dan ook het juiste schema opzoeken
Man kann dem Speicher (durchgeheizt auf 65°C) 175 l Trinkwasser (von 10° auf 45° aufgeheizt) entnehmen ohne nachzuheizen. Aufgrund des großen WT ist die Zapfrate in einem EFH da relativ egal. Danach hängt es von der Nachheizung ab wie viel Warmwasser man entnehmen kann.
ik heb u de gegevens naar [email protected] gestuurd
Deze boiler is een hygiëne boiler. Het tapwater wordt volgens het principe van een doorstroomverwarmer verwarmd, dat gebeurt in de RVS buis. Het CV water zit in de boiler, om de RVS spiraal heen. Het CV water kan door de extra warmtewisselaar met behulp van solar verwarmd worden.
bonjour pouvez vous nous faire parvenir le coefficient de perte statique du produit 516008266