You are using an outdated browser. Please update your browser now to display the page correctly.
Delivery the next working day
Right of return 14 days
This buffer storage tank fulfills the highest demands on heat storage. Due to its highly efficient insulation, the heat-retaining loss is significantly reduced compared to common storage tanks...
All product informationStorage tanks A+
10-year warranty
High Quality
TÜV Rheinland
Delivery by forwarding agency
This buffer storage tank fulfills the highest demands on heat storage. Due to its highly efficient insulation, the heat-retaining loss is significantly reduced compared to common storage tanks. The purpose of the buffer storage tank is to balance the difference between generated heat and consumed heat. So the heat generators can be operated more independently from the consumption.
For more information see Downloads
Rated volume according to EN 12897: | 300 |
Colour: | silver |
Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
Weight [kg]: | 71 |
Total height including insulation [mm]: | 1750 |
Diameter with insulation [mm]: | 610 |
Tilt height [mm]: | 1830 |
Energy efficiency class according to EU regulation no. 812/2013: | A+ |
Heat retaining loss according to EN 12897 [W]: | 36 |
Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,864 |
Real volume according to EN 12897 [l]: | 298 |
pmax Tank [bar]: | 3 |
tmax Tank [°C]: | 95 |
tmin Tank [°C]: | 20 |
Connection layout: | 180° |
Connection sensor [Ø mm / terminal]: | 6 mm |
Connection heat generator [thread]: | R 1" |
Connection heating element [thread]: | Rp 1 1/2" |
Max. immersion depth of screw-in heater [mm]: | 500 |
oui, le ballon est actuellement disponible. La jaquette est livrée separément mais l´iIsolation en mousse de qualité A+ est non amovible.
Hello, I am looking at buffer storage tank PS 300 (without heat exchanger). Is there an indication against installing a heating element at port P located at the bottom of the tank rather than at port O (labelled for this purpose) ? I am looking to heat the whole volume of the tank and not just the upper part. Thanks.
You can install the heating element at port P.
Bonjour, Je souhaiterais avoir la fiche technique, j ai besoin d elements, nombre de piquages, dimensions, etc.. concernant, le 300l, 400l 500l. Bien cordialement [email protected]
Bonjour,
Voustrouveztouteslesfichestechniquessous la rubrique "Downloads" - "Fichetechnique"
Geachte,
Deze standaard uitvoering is helaas niet geschickt voor koeling. Deze gaat condenseren wat voor roest aan de buitenlaag gaat zorgen, waardoor de boiler gaat beschadigt geraken in loop van tijd.
Op aanvraag kunnen wij een boiler leveren met speciale lak behandeling, deze wordt dan echter zonder isolatie aangeboden en moet nog door u voorzien worden.
Mvg,
OEG