You are using an outdated browser. Please update your browser now to display the page correctly.
The OEG SilverTec multilayer composite pipe is versatile for heating and cooling systems as well as for drinking water and sanitary installations.
It consists of an extruded basic polyethylene...
certified by DVGW
kiwa-certified
Suitable for sanitary installation
Suitable for surface and ceiling heating
Suitable for surface and ceiling cooling
Suitable for radiator connection
SKZ
The OEG SilverTec multilayer composite pipe is versatile for heating and cooling systems as well as for drinking water and sanitary installations.
It consists of an extruded basic polyethylene pipe with aluminium jacket covered
with a layer of white polyethylene for protection. The dimensionally stable joint can be easily bent by hand and remains in the desired shape without springback.
Due to the low roughness of the cross-linked plastic, there are no material removals or deposits within the pipe. The smooth inner wall does not cause any audible flow noises.
Thermal expansion is comparable to that of metal pipes. The pipe is absolutely impermeable.
The OEG SilverTec multilayer composite pipe complies with the UBA positive list and has DVGW and KIWA approvals. It is suitable for all types of drinking water.
For more information see Downloads
| OEG no. | 802029960 |
| PU | 50 metres |
| Size [mm]: | 16 x 2 |
| Colour: |
Blue |
| Insulation thickness [mm]: | 6 |
| Wall thickness [mm]: | 2 |
| Permanent temperature [°C]: | 70 |
| Operating temperature max. [°C]: | 95 |
| Pressure max. [bar]: | 10 |
| Manufacturer | OEG |
| Brand | SilverTec® |
| EAN | 4260494170313 |
| Also replaces |
|
| Weight [kg] | 6.75 |
| Notes |
certified by DVGW kiwa-certified Suitable for sanitary installation Suitable for surface and ceiling heating Suitable for surface and ceiling cooling Suitable for radiator connection SKZ |
| Customs tariff number | 39173900 (IT) |
Protection incendie : auto-extinguible / Classe B 1, il faut comparer si cela est suffisant avec les réglementations locales.
Le tuyau isolé peut être posé dans la chape, mais les pièces de raccordement doivent ensuite également être isolées.
Die Rohre gibt es leider nur mit roter Isolierung.
Nous allons renseigner auprès de notre fournisseur
En ce qui concerne les épaisseurs d'isolation, il s'agit de respecter les prescriptions du décret sur la protection énergétique.
Diamètre total: env. 2,5 cm
Dit product is momenteel in productie en zal begin volgende week weer uit voorraad leverbaar zijn.
En principe, les tuyaux multicouches en aluminium peuvent également être utilisés à l'extérieur. Une température minimale n'est pas pertinante ici. En cas de températures inférieures à 0°C, le système doit être vidé ou maintenu hors gel par du glycol.
Cependant la protection contre les UV est particulièrement importante : la couche extérieure en PE de l'isolation - comme presque toutes les matières plastiques - n'est que partiellement résistante aux UV. L'idéal est donc de protéger le tuyaux des rayons UV à l'extérieur par une isolation en métal/aluminium.
non, bleu seulement livrable en 6 mm et rouge en 10 mm
La fiche technique est disponible en téléchargement sous Downloads Aluminium multi-layer pipe 20 x 2 mm with insulation10 mm
Le tuyau multicouche est conforme aux normes DIN 16833/16834. Il peut être utilisé de nombreuses manières pour les systèmes de chauffage et de refroidissement ainsi que pour les installations d'eau potable et sanitaires.
La couronne n'existe pas en diamètre 32.
Ciò non è possibile senza un ulteriore isolamento, come ad esempio SH Armaflex art. n. SH/Armaflex self-adhesive 22 x 24 mm
Goedemorgen,
De buis is niet geschikt voor stadsverwarming, omdat deze permanent hogere temperaturen kan genereren. Hierbij is het gebruik van metalen buizen aan te raden.
Goedemorgen,
hiervoor kunt u Two-screw pipe clamps galvanised M8 x 26-30 mm (3/4") gebruiken, dan hoeft u alleen nog te bepalen welke lengte de stokschroeven moeten hebben.
Hallo, er vroeg iemand of deze buizen geschikt zijn voor perskoppelingen van Begetube? Waarbij jullie antwoorden: ja de buis is ook geschikt voor perskoppelingen van Begetube. Echter, ik lees in de garantie voorwaarden dan er 10 jaar garantie is vanaf de aankoopdatum als zowel de buis als de fittingen silvertec zijn... Moeten we hieruit concluderen dat er dan geen garantie is bij gebruik Begetube fittingen? Jullie verkochten vroeger Comisa buizen en koppelingen, wat vervelend is aangezien er een zeker moment koppelingen zullen gemengd voorkomen in installaties (oa opgebruiken stock)... Kan u dit verduidelijken ?
Goedemorgen,
U verwijst waarschijnlijk niet naar de garantie, maar naar de door ons verlengde garantie. Deze uitbreiding van de garantie is alleen van toepassing op complete systemen van SilverTec. Als u het systeem combineert, is de wettelijke garantie van toepassing.
Goedemorgen,
Nee, deze buis is niet geschikt om in de grond te leggen zonder aanvullende bescherming.
Goedemorgen,
datklopt, blauweisolatie 6 mm, rode 10 mm
Bonjour,
Le tuyau multicouche n´est pas livrable en rouge avec une isolation de 6mm.
Seulement en bleu: Aluminium multilayer pipe 16 x 2 mm with insulation 6 mm.
10 mm is juist
Bonjour,
Le tuyau multicouche aluminium 26 x 3 mm en rouge existe seulement en 10 mm.C´est la réf Alumiium multi-layer pipe 16 x 2 mm with insulation 10 mm
Le bleu est pour l'eau froide et le rouge pour l'eau chaude. Dans ce dernier cas, les différences de température sont plus importantes, de sorte que l'isolation doit être plus épaisse.
Goedemiddag, ja de buis is ook geschikt voor perskoppelingen van Begetube.
Ja, dat is mogelijk
16 x 2,0 - 0,20 mm
20 x 2,0 - 0,20 mm
26 x 3,0 - 0,35 mm
32 x 3,0 - 0,50 mm
40 x 3,5 - 0,50 mm
50 x 4,0 - 0,60 mm
63 x 4,5 - 0,80 mm
Ja, dezebuisheefteen kiwakeurmerk .
Goedemorgen, deze zijn enkel in rood en blauw leverbaar
Nee, het is niet mogelijk om een andere buis met de fittingen te gebruiken. Dus ofwel moet de klant onze fittingen of de bijbehorende Comap-buis kopen.
your data sheet says max 6 bar but you write 10 bar on your website, what is correct ?
Hello, the data sheet refers to the indication of the short-term operation at a temperature of +95 °C, then there is an operating pressure of a maximum of 6 bar advised. In a continuous operation, a temperature of +70 °C, at an operating pressure of 10 bar is approved.
Oui, c'est la référence Alumiium multi-layer pipe 16 x 2 mm with insulation 10 mm.
nous ne le conseillons pas