Premium REVERSE+ heat pump combination cylinder that can be used not only for domestic hot water heating but also for cooling and heating. The large heat exchanger surface of the twin coil is specially...
All product informationPremium REVERSE+ heat pump combination cylinder that can be used not only for domestic hot water heating but also for cooling and heating. The large heat exchanger surface of the twin coil is specially designed for heating and supplying domestic hot water in combination with heat pumps and solar systems. The additional buffer tank increases the volume of the heating circuit and thus prevents the heat pump from short‑cycling. The buffer section is thermally separated from the DHW section and can therefore be used independently for cooling or heating surface heating systems.
To protect the cylinder surface from condensate in cooling mode, the cylinder features a special, high‑quality anti‑corrosion coating. As cooling temperatures combined with higher ambient temperatures can lead to condensation, special protection of the system components involved is required. The high‑grade A⁺ insulation from OEG also ensures minimal temperature losses with these cylinders.
To supplement the heat pump heating system, an optional immersion heater can be operated both in the DHW cylinder and in the buffer tank below.
For more information see Downloads
| OEG no. | 516005660 |
| Smooth tube heat exchanger: | 1 |
| Tank capacity [litres]: | 203 | 100 |
| Recommended for: | Heat pumps |
| Operating mode: | bivalent |
| Installation type: | Vertical storage tank |
| Manufacturer | OEG |
| Brand | Reverse+ |
| Energy efficiency class | A+ |
| ErP-Label |
|
| Notes | |
| Customs tariff number | 84191900 |
| Colour: | silver |
| Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
| Weight [kg]: | 125 |
| Total height including insulation [mm]: | 1235 |
| Diameter with insulation [mm]: | 760 |
| Tilt height [mm]: | 1460 |
| Energy efficiency class according to EU regulation no. 812/2013: | A+ |
| Heat retaining loss according to EN 12897 [W]: | 36 |
| Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,864 |
| Output capacity (45°C) [l]: | 259 |
| Performance indicator NL following DIN 4708: | 5 |
| Real volume according to EN 12897 [l]: | 303 |
| pmax Tank [bar]: | 3 |
| tmax Tank [°C]: | 95 |
| tmin Tank [°C]: | 10 |
| tmax Ambient air [°C]: | 30 |
| Max. rel. air humidity [%]: | 80 |
| Buffet storage tank capacity (part of the actual capacity) [l]: | 100 |
| Domestic hot water tank volume (Part of the real volume) [l]: | 203 |
| pmax Domestic hot water tank [bar]: | 10 |
| tmax Domestic hot water tank [°C]: | 95 |
| Smooth-pipe heat exchanger [number]: | 1 |
| Smooth-pipe heat exchanger area bottom [m²]: | 1,20 |
| Smooth-pipe heat exchanger volume bottom: | 7,90 |
| pmax Smooth-pipe heat exchanger [bar]: | 10 |
| tmax Smooth-pipe heat exchanger [°C]: | 130 |
| Connection layout: | 180° |
| Connection sensor [Ø mm / terminal]: | 6 mm |
| Connection cold / hot water: | R 1" |
| Connection heat generator [thread]: | R 1" |
| Connection heat exchanger [thread]: | Rp 1 1/2" |
| Connection circulation: | R 3/4" |
| Connection heating element [thread]: | Rp 1 1/2" |
| Service hatch (LK 150): | 115 / 180 |
| Max. immersion depth of flange heater [mm]: | 490 |
| Max. immersion depth of screw-in heater [mm]: | 600 |
|
|
|
| OEG no. | 516005660 |
| Smooth tube heat exchanger: | 1 |
| Tank capacity [litres]: | 203 | 100 |
| Recommended for: | Heat pumps |
| Operating mode: | bivalent |
| Installation type: | Vertical storage tank |
| Brand | Reverse+ |
| Notes | |
| Customs tariff number | 84191900 |
| Colour: | silver |
| Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
| Weight [kg]: | 125 |
| Total height including insulation [mm]: | 1235 |
| Diameter with insulation [mm]: | 760 |
| Tilt height [mm]: | 1460 |
| Energy efficiency class according to EU regulation no. 812/2013: | A+ |
| Heat retaining loss according to EN 12897 [W]: | 36 |
| Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,864 |
| Output capacity (45°C) [l]: | 259 |
| Performance indicator NL following DIN 4708: | 5 |
| Real volume according to EN 12897 [l]: | 303 |
| pmax Tank [bar]: | 3 |
| tmax Tank [°C]: | 95 |
| tmin Tank [°C]: | 10 |
| tmax Ambient air [°C]: | 30 |
| Max. rel. air humidity [%]: | 80 |
| Buffet storage tank capacity (part of the actual capacity) [l]: | 100 |
| Domestic hot water tank volume (Part of the real volume) [l]: | 203 |
| pmax Domestic hot water tank [bar]: | 10 |
| tmax Domestic hot water tank [°C]: | 95 |
| Smooth-pipe heat exchanger [number]: | 1 |
| Smooth-pipe heat exchanger area bottom [m²]: | 1,20 |
| Smooth-pipe heat exchanger volume bottom: | 7,90 |
| pmax Smooth-pipe heat exchanger [bar]: | 10 |
| tmax Smooth-pipe heat exchanger [°C]: | 130 |
| Connection layout: | 180° |
| Connection sensor [Ø mm / terminal]: | 6 mm |
| Connection cold / hot water: | R 1" |
| Connection heat generator [thread]: | R 1" |
| Connection heat exchanger [thread]: | Rp 1 1/2" |
| Connection circulation: | R 3/4" |
| Connection heating element [thread]: | Rp 1 1/2" |
| Service hatch (LK 150): | 115 / 180 |
| Max. immersion depth of flange heater [mm]: | 490 |
| Max. immersion depth of screw-in heater [mm]: | 600 |
Wat is het vermogen van het spiraal bij een vat van 300 liter?
Vermogen: 259 Liter
Kenmerk NL: 5
Vu le volume de l'échangeur de 15L selon mes calculs la surface doit faire 1,2m² x 2 soit total de 2,4m²
1.3 m² x 2 = 2,6 m²
Pouvez-vous me confirmer la surface de l'échangeur? 1,2m² me semble trop petit pour une pompe à chaleur
L'espace disponible est limité et il n'est pas possible d'y intégrer un échangeur plus grand. Celui existant est un échangeur double