Diaphragm gas meter with two-pipe connection DN40

OEG no.: 135450120
  • BK-G16
  • 2" ET
Zoom Diaphragm gas meter with two-pipe connection DN40

Folded two-pipe gas meter with high measuring accuracy and safety for household and business. The low-noise and calibrated measuring unit operates on the principle of pneumatic control.

All product information
certified by DVGW

certified by DVGW

certified by DVGW
CE

CE

CE
Wipe 'n' Buy ®

Folded two-pipe gas meter with high measuring accuracy and safety for household and business. The low-noise and calibrated measuring unit operates on the principle of pneumatic control.


For more information see Downloads


OEG no. 135450120
Design: Two-pipe meter
Type: BK-G16
Volume flow [m³/h]: 0.16 .. 25
Connection size: 2" ET
Nominal flow diameter: DN40
Media: Natural gas, Town gas, Propane, Butane, Air, Inert gases
Media temperature [°C]: -10 .. 40
Approval: MID conformity, PTB
Operating pressure max. [bar]: 0.5
Weight [kg] 6.2
Notes
certified by DVGW

certified by DVGW

certified by DVGW
CE

CE

CE
Customs tariff number 90281000
en
Question (Design: Two-pipe meter | Type: BK-G16 | Connection size: 2" ET)

bonjour, ce compteur est-il fournit avec un certificat de calibration et d'étalonnage officiel?

Answer OEG:

Non, il est livré sans certificat

en
Question (Design: Two-pipe meter | Type: BK-G16 | Connection size: 2" ET)

Für wie lange ist der Zähler ab Liefertermin geeicht ? MFG Niehaus

Answer OEG:

Guten Morgen.

Dieser Zähler ist ein G16- Zähler. diese haben eine Eichzeit von 16 Jahren. Dieser Zähler ist bis 2038 geeicht.

en
Question (Design: Two-pipe meter | Type: BK-G16 | Connection size: 2" ET)

Bonjour Quelle est la dimension du filetage nécessaire pour équiper ce compteur que je puisse vous les commander en même temps. cordialement

Answer OEG:

Bonjour,

2''.

en
Question (Design: Two-pipe meter | Type: BK-G16 | Connection size: 2" ET)

Wat is het artikelnummer van bijbehorende puls doorgever?

Answer OEG:

Goedemorgen,

dat is het artikel Impulsgenerator IN-Z61 uitbreidingsset BK G 2,5 tot BK G 100, incl. stekker - Pulse transmitter IN-Z61 retrofit kit BK G 2.5 - to BK G 100, incl. plug.

en
Question (Design: Two-pipe meter | Type: BK-G16 | Connection size: 2" ET)

Kann der Gaszähler auch für Flüssiggas eingesetzt werden?

Answer OEG:

Hallo,

der Zähler ist nur für Erdgas, Stadtgas, Propan, Luft, Butan und inerte Gase geeignet.

You have to be logged in to ask a question

No customer reviews yet