You are using an outdated browser. Please update your browser now to display the page correctly.
Innovative fresh-water storage tank with separate buffer unit for heating water. Ideal for low system temperatures and efficient use of heat pumps with high output capacities in domestic hot water production at the same...
All product informationInnovative fresh-water storage tank with separate buffer unit for heating water. Ideal for low system temperatures and efficient use of heat pumps with high output capacities in domestic hot water production at the same. The lower buffer storage tank section provides sufficient capacity for the use as heating water reservoir. The clear separation of the two tank sections allows for large temperature differences. That is why it is possible to use the buffer section for cooling in combination with a heat pump. The integrated stainless steel heat exchanger provides hygienically clean drinking water at any time and does not need an anode. The high-quality vacuum insulation guarantees low heat losses. For both storage tank sections, there is the option to install a heating element.
For more information see Downloads
| OEG no. | 516005924 |
| Tank capacity fresh-water type [litres]: | 242 |
| Tank capacity buffer-type [litres]: | 167 |
| Recommended for: | Heat pumps |
| Smooth tube heat exchanger: | 0 |
| Installation type: | Vertical storage tank |
| Manufacturer | OEG |
| Brand | Reverse+ |
| Energy efficiency class | A+ |
| ErP-Label |
|
| Notes | |
| Customs tariff number | 84191900 |
| Colour: | silver |
| Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed PU insulation |
| Weight [kg]: | 126 |
| Total height including insulation [mm]: | 1450 |
| Diameter with insulation [mm]: | 760 |
| Tilt height [mm]: | 1710 |
| Energy efficiency class according to EU regulation no. 812/2013: | A+ |
| Heat retaining loss according to EN 12897 [W]: | 39 |
| Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,936 |
| Output capacity (45°C) [l]: | 140 |
| Performance indicator NL following DIN 4708: | 1,60 |
| Real volume according to EN 12897 [l]: | 409 |
| pmax Tank [bar]: | 3 |
| tmax Tank [°C]: | 95 |
| tmin Tank [°C]: | 6 |
| tmax Ambient air [°C]: | 30 |
| Max. rel. air humidity [%]: | 80 |
| Buffet storage tank capacity (part of the actual capacity) [l]: | 167 |
| DHW heat exchanger area [m²]: | 3,20 |
| DHW heat exchanger volume [l]: | 14 |
| pmax DHW heat exchanger [bar]: | 6 |
| tmax DHW heat exchanger [°C]: | 95 |
| Connection layout: | 180° |
| Connection sensor [Ø mm / terminal]: | 6 mm |
| Connection heat generator [thread]: | Rp 1 1/2" |
| Connection heating element [thread]: | Rp 1 1/2" |
| Max. immersion depth of screw-in heater [mm]: | 600 |