HeatBloC unmixed pump group without pump

OEG no.: 512244474
  • Also replaces
    schließen Also replaces:
    • 512245000 (Connection system M2-130 DN 20)
Zoom HeatBloC unmixed pump group without pump

Heating circuit station for systems with direct flow temperatures.

This ready-to-connect pump group enables quick, tidy installation of direct heating circuits when you are using a separately mounted circulation pump...

All product information
Wipe 'n' Buy ®

Heating circuit station for systems with direct flow temperatures.

This ready-to-connect pump group enables quick, tidy installation of direct heating circuits when you are using a separately mounted circulation pump. The smart combination of thermometer ball valve, integrated gravity brake and prepared pump ball valve saves installation time and makes future maintenance straightforward.

The compact unit really comes into its own in systems with constant flow temperature, as well as for cylinder or buffer tank charging – space-saving, functional and adaptable. You benefit from maximum flexibility in pump selection and can cut costs if a suitable pump is already installed in the system.

A practical solution for anyone who wants to operate heating circuits efficiently without mixing technology.

Technical data:
• Maximum output at a temperature differential of 20 K: 46 kW

 


For more information see Downloads


OEG no. 512244474
Material: Brass
Insulation: EPP
Seal: NBR, EPDM
Operating temperature max. [°C]: 110
kvs-value [m³/h]: 6.0
Connection boiler circuit: 1 1/2" ET
Connection heating circuit: 1" IT
Axial dimension: 125
Length x Width [mm]: 330 x 250
Suitable for pump connection size [inch]: 1 1/2
Nominal size [DN]: 25
Nominal pressure PN [bar]: 6
Function: Unmixed heating circuit
Pump type: without
Type: HeatBloC Eco
Also replaces
  • 512245000 (Connection system M2-130 DN 20)
Weight [kg] 3.15
Customs tariff number 84136080
en
Question (Function: Unmixed heating circuit | Pump type: without)

Buon pomeriggio, vorrei sapere se per questo codice è possibile avere come ricambio i termometri rosso e blu, Grazie mille

Answer OEG:

Riceverete una nostra offerta al più presto.

en
Question (Function: Unmixed heating circuit | Pump type: without)

Bonjour, Suite achat de HeatBloCEco sur votre site, où pouvons-nous trouver le moteur SR5 en pièce de rechange ? Merci d'avance pour votre réponse.

Answer OEG:

Bonjour,

Nous vous avons envoyé une offre de prix par mail.

en
Question (Function: Unmixed heating circuit | Pump type: Wilo Yonos Para RS 25/6)

Peut on inverser l'aller et le retour.

Answer OEG:

techniquement on peut le changer mais l'isolation ne va plus convenir apres

en
Question (Function: Unmixed heating circuit | Pump type: without)

Ist der Mischermotor dabei?

Answer OEG:

Ja, ein Stellmotor SR5 (230V) ist dabei.