Plate heat exchanger PWT50 with 60 plates

OEG no.: 513000174
  • Also replaces
    schließen Also replaces: 513000158 (Plate heat exchanger GPWT 45 - 40)
Zoom Plate heat exchanger PWT50 with 60 plates
OEG no. : 513000174

The brazed plate heat exchanger consists of profiled, embossed stainless steel plates turned by 180° in opposition to each other. Due to the thermodynamically optimised corrugation, highly turbulent fluid channels are created with a very efficient heat transfer at low pressure losses...

All product information
Related products
Wipe 'n' Buy ®
Wipe 'n' Buy

The brazed plate heat exchanger consists of profiled, embossed stainless steel plates turned by 180° in opposition to each other. Due to the thermodynamically optimised corrugation, highly turbulent fluid channels are created with a very efficient heat transfer at low pressure losses. A maximum heat transfer is achieved by standardly directing the warm and cold fluids in alternating channels through the heat exchanger.
The plate heat exchanger with a glycol content of up to 40% is solar-compatible and with a chloride content of up to 150 mg/l it is also swimmingpool-compatible.

Note:
Bolted heat exchangers and other sizes on request!


For more information see Downloads


OEG no. 513000174
Plates: 60
Width [mm]: 124
Height [mm]: 304
Material: Stainless steel 1.4401
Connection: 1" ET
Surface: 1.83 m²
Media: Water with up to 40 % glycol
Operating pressure max. [bar]: 30
Temperature max. [°C]: 200
Type: PWT 50
Manufacturer OEG
Also replaces 513000158
Weight [kg] 5.94
Customs tariff number 84195080
en
Question:

Kunnen deze warmtewisselaars ook toegepast worden voor warmtepompen? maw, afgifte van armte of koeling van frigotechsche installatie naar water? Effectief een frigotechnische scheiding ? temperaturen en drukken lijken me geen probleem.. zijn er andere zaken?

Answer OEG:

De warmtewisselaars kunnen voor warmtepompen gebruikt worden.

en
Question:

hebben jullie een tabel met daarin de weerstanden van de wisselaars bij de verschillende volumestromen?

Answer OEG:

Goedemorgen,

helaas kunnen wij een dergelijke tabel niet leveren.

Question:

Dear Sirs: regarding this heat exchanger, I would like to have more information. Mainly: rated power of HX, with what inlet/outlet temperatures; overal transfer quoficient (UA factor); nominal flowrates for cold and hot sides; expected pressure loss at 60/ 100 plates plates; what is the expected efficiency. Thank you in advance.

Answer OEG:

More Informations are on the site from the item.The technical data is on the site in tab ( Downloads ) next Product informations.The power is diffrent, because we don`t know the temperatures inside the exchanger and outside.

Look in thetechnicaldata

 

 

Question:

Could you provide technical information of this heat exchanger?

Answer OEG: Hello, The technical Information is now available for download. Kind Regards, OEG

You have to be logged in to ask a question